Please use this identifier to cite or link to this item:
https://dspace.sti.ufcg.edu.br/handle/riufcg/44657Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.creator.ID | MEDEIROS, F. L. S. | pt_BR |
| dc.creator.Lattes | http://lattes.cnpq.br/4867069854979363 | pt_BR |
| dc.contributor.advisor1 | SERRES, Alexandre Jean René. | - |
| dc.contributor.advisor1ID | SERRES, A. J. R. | pt_BR |
| dc.contributor.advisor1Lattes | http://lattes.cnpq.br/5988817460788034 | pt_BR |
| dc.contributor.referee1 | SERRES, Georgina Karla de Freitas. | - |
| dc.contributor.referee1ID | SERRES, G. K. F. | pt_BR |
| dc.contributor.referee1Lattes | http://lattes.cnpq.br/0137382086087353 | pt_BR |
| dc.description.resumo | Este trabalho propõe um ressonador em forma de alça (Hairpin) implementado com uma estrutura de solo defeituosa (DGS) para otimizar a sensibilidade no monitoramento de soluções de glicose. A estrutura projetada exibe duas frequências de ressonância: uma a 2,15 GHz com -35,82 dB e outra a 3,81 GHz com -31,43 dB. Um conjunto de simulações foi realizado para comparar a sensibilidade da estrutura com e sem a DGS. Essas simulações consideraram duas configurações de posicionamento de amostra diferentes: uma onde as soluções de água e glicose foram colocadas sobre as linhas de alimentação e elementos metálicos da estrutura, e outra onde as soluções foram colocadas diretamente sobre o plano de terra. Independentemente do posicionamento da amostra, a estrutura com o solo defeituoso demonstrou consistentemente maior sensibilidade, tornando-a uma candidata promissora para aplicações de monitoramento de nível de glicose. | pt_BR |
| dc.publisher.country | Brasil | pt_BR |
| dc.publisher.department | Centro de Engenharia Elétrica e Informática - CEEI | pt_BR |
| dc.publisher.initials | UFCG | pt_BR |
| dc.subject.cnpq | Engenharia Elétrica | pt_BR |
| dc.title | Estrutura radiométrica com plano terra defeituoso para monitoramento não invasivo de índice glicêmico. | pt_BR |
| dc.date.issued | 2025-10-01 | - |
| dc.description.abstract | This work proposes a hairpin-shaped resonator implemented with a defective ground structure (DGS) to optimize sensitivity in glucose solution monitoring. The designed structure exhibits two resonance frequencies: one at 2.15 GHz with -35.82 dB and another at 3.81 GHz with -31.43 dB. A set of simulations was carried out to compare the sensitivity of the structure with and without the DGS. These simulations considered two different sample positioning configurations: one where the water and glucose solutions were placed over the feedlines and metallic elements of the structure and another where the solutions were placed directly on the ground plane. Regardless of the sample positioning, the structure with the defective ground consistently demonstrated higher sensitivity, making it a promising candidate for glucose level monitoring applications. | pt_BR |
| dc.identifier.uri | https://dspace.sti.ufcg.edu.br/handle/riufcg/44657 | - |
| dc.date.accessioned | 2025-12-17T18:14:29Z | - |
| dc.date.available | 2025-10-01 | - |
| dc.date.available | 2025-12-17T18:14:29Z | - |
| dc.type | Trabalho de Conclusão de Curso | pt_BR |
| dc.subject | Sensor não invasivo | pt_BR |
| dc.subject | Ressonador | pt_BR |
| dc.subject | Micro-ondas | pt_BR |
| dc.subject | Baixo custo | pt_BR |
| dc.subject | Diabetes | pt_BR |
| dc.subject | Monitoramento de índice glicêmico | pt_BR |
| dc.subject | Non-invasive sensor | pt_BR |
| dc.subject | Resonator | pt_BR |
| dc.subject | Microwave | pt_BR |
| dc.subject | Low Cost | pt_BR |
| dc.subject | Glucose | pt_BR |
| dc.subject | Glycemic Index Monitoring | pt_BR |
| dc.rights | Acesso Aberto | pt_BR |
| dc.creator | MEDEIROS, Felipe Lucena Souza. | - |
| dc.publisher | Universidade Federal de Campina Grande | pt_BR |
| dc.language | por | pt_BR |
| dc.title.alternative | Radiometric Structure with Defective Ground Plane for Non-Invasive Glycemic Index Monitoring. | pt_BR |
| dc.identifier.citation | MEDEIROS, Felipe Lucena Souza. Estrutura radiométrica com plano terra defeituoso para monitoramento não invasivo de índice glicêmico. 2025. 49f. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Elétrica) - Universidade Federal de Campina Grande, Centro de Engenharia Elétrica e Informática, Campina Grande, Paraíba, Brasil, 2025. Disponível em: https://dspace.sti.ufcg.edu.br/handle/riufcg/44657 | pt_BR |
| Appears in Collections: | Curso de Bacharelado em Engenharia Elétrica - CEEI - Monografias | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| FELIPE LUCENA SOUZA MEDEIROS-TCC-CEEI-ENGENHARIA ELETRICA-(2025).pdf | FELIPE LUCENA SOUZA MEDEIROS-TCC-CEEI-ENGENHARIA ELETRICA-(2025) | 1.02 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.