Please use this identifier to cite or link to this item: https://dspace.sti.ufcg.edu.br/handle/riufcg/47450
Full metadata record
DC FieldValueLanguage
dc.creator.IDGUIMARÃES, B. F.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/8115895270222385pt_BR
dc.contributor.advisor1FARIAS NETO, Severino Rodrigues de.-
dc.contributor.advisor1IDFARIAS NETO, S. R.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/5029314237107938pt_BR
dc.contributor.referee1FARIAS, Fabiana Pimentel Macêdo.-
dc.contributor.referee2SOUZA, Edna Cordeiro de.-
dc.contributor.referee3LIMA , Antonio Gilson Barbosa de.-
dc.contributor.referee4ANDRADE, Tony Herbert Freire de.-
dc.description.resumoA escassez de água potável é um dos maiores desafios globais contemporâneos, exigindo o desenvolvimento de tecnologias sustentáveis e energeticamente eficientes de dessalinização. Neste trabalho, propõe-se a utilização de um ciclone equipado com bicos aspersores como unidade alternativa de dessalinização de água salina. O estudo foi conduzido por meio de simulação numérica utilizando o software ANSYS Fluent, adotando a abordagem Euleriana- Lagrangiana para o rastreamento das partículas de água salina e o modelo Reynolds Stress Model (RSM) para a modelagem da turbulência. Foram avaliados os fenômenos de transferência de massa e de calor, considerando a evaporação da fase aquosa, bem como a influência de parâmetros operacionais e geométricos, tais como a temperatura e a velocidade de entrada do ar, a temperatura da água alimentada pelos bicos aspersores, e a quantidade, posição e inclinação dos aspersores. Os resultados indicaram que o aumento da velocidade de entrada do ar intensifica o gradiente de pressão e promove maior arraste de vapor na região central, enquanto o posicionamento e a inclinação dos bicos influenciam significativamente o campo térmico e a eficiência da evaporação. As análises de fração mássica de vapor, pressão e velocidade demonstraram comportamento coerente com a dinâmica típica dos ciclones, validando o modelo proposto. Adicionalmente, os resultados numéricos evidenciaram diferenças expressivas de desempenho entre os cenários simulados. Nos casos 1 a 9, as maiores eficiências de evaporação foram observadas nos Casos 2 e 8, ambos com 1,61%, considerando uma vazão mássica de água injetada de aproximadamente 2018 kg/h. Entre os casos 10 a 18, os melhores desempenhos ocorreram nos Casos 15 e 17, que apresentaram vazões mássicas de vapor na saída superior de 34,4 kg/h e 36,6 kg/h, com eficiências de evaporação de 1,71% e 1,82%, respectivamente. Quando a velocidade de entrada do ar foi elevada para 55 m/s (Caso 19), observou-se aumento adicional da eficiência no overflow e uma razão entre as vazões mássicas de vapor nas saídas superior e inferior de 3,21, indicando forte predominância do transporte axial ascendente. Contudo, esse ganho veio acompanhado de aumento significativo do custo energético específico, que passou de aproximadamente 7,6 W por kg/h no Caso 2 para cerca de 160 W por kg/h no Caso 19, evidenciando o compromisso entre intensificação da evaporação e consumo energético. Conclui-se que o uso de ciclones munidos de aspersores apresenta potencial técnico para aplicação em processos de dessalinização, especialmente por serem um sistema compacto e de baixo custo energético.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA DE PROCESSOSpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia de Processospt_BR
dc.titleAnálise de CFD Multifásica da evaporação induzida por atomização em ciclone aplicado a dessalinização.pt_BR
dc.date.issued2026-02-26-
dc.description.abstractPotable water scarcity is one of the greatest contemporary global challenges, demanding the development of sustainable and energy-efficient desalination technologies. This work proposes the use of a cyclone equipped with spray nozzles as an alternative desalination unit for brackish water. The study was conducted through numerical simulation using ANSYS Fluent software, adopting the Eulerian-Lagrangian approach for tracking brackish water particles and the Reynolds Stress Model (RSM) for turbulence modeling. Mass and heat transfer specifications were evaluated, considering wet-phase evaporation, as well as the influence of operational and geometric parameters, such as air inlet temperature and velocity, the temperature of the water fed by the spray nozzles, and the quantity, position, and specification of the spray nozzles. The results indicated that increasing the air inlet velocity intensifies the pressure gradient and promotes greater vapor entrainment in the central region, while the positioning and inclination of the nozzles significantly influence the thermal field and evaporation efficiency. Analyses of vapor mass fraction, pressure, and velocity demonstrated behavior consistent with the typical dynamics of cyclones, validating the proposed model. Additionally, the numerical results revealed significant performance differences among the simulated scenarios. For Cases 1 to 9, the highest evaporation efficiencies were observed in Cases 2 and 8, both reaching 1.61%, considering an injected water mass flow rate of approximately 2018 kg/h. Among Cases 10 to 18, the best performances were obtained in Cases 15 and 17, which presented vapor mass flow rates at the upper outlet of 34.4 kg/h and 36.6 kg/h, with evaporation efficiencies of 1.71% and 1.82%, respectively. When the air inlet velocity was increased to 55 m/s (Case 19), a further increase in overflow efficiency was observed, along with a ratio of 3.21 between the vapor mass flow rates at the upper and lower outlets, indicating a strong predominance of upward axial transport. However, this improvement was accompanied by a significant rise in specific energy cost, which increased from approximately 7.6 W per kg/h in Case 2 to about 160 W per kg/h in Case 19, highlighting the trade-off between evaporation intensification and energy consumption. It is concluded that the use of cyclones equipped with sprinklers presents technical potential for application in desalination processes, especially because they are a compact system with low energy costs.pt_BR
dc.identifier.urihttps://dspace.sti.ufcg.edu.br/handle/riufcg/47450-
dc.date.accessioned2026-07-03T18:01:52Z-
dc.date.available2026-07-03-
dc.date.available2026-07-03T18:01:52Z-
dc.typeTesept_BR
dc.subjectTransferência de Calor e Massapt_BR
dc.subjectModelo Lagrangianopt_BR
dc.subjectSimulação CFDpt_BR
dc.subjectCiclonept_BR
dc.subjectDessalinizaçãopt_BR
dc.subjectHeat and Mass Transferpt_BR
dc.subjectLagrangian Modelpt_BR
dc.subjectCyclone: CFD Simulationpt_BR
dc.subjectDesalination;pt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorGUIMARÃES , Bruno Formiga.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeMultiphase CFD analysis of atomization-induced evaporation in a cyclone applied to desalination.pt_BR
dc.identifier.citationGUIMARÃES, Bruno Formiga. Análise de CFD Multifásica da evaporação induzida por atomização em ciclone aplicado a dessalinização. 2026. 172 f. Tese (Doutorado em Engenharia de Processos) – Programa de Pós-Graduação em Engenharia de Processos, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2026.pt_BR
Appears in Collections:Doutorado em Engenharia de Processos.

Files in This Item:
File Description SizeFormat 
BRUNO FORMIGA GUIMARÃES - TESE - (PPGEP) 2026.pdf3.76 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.