| dc.description.resumo | A crescente inserção de veículos elétricos (VEs) desloca parte do consumo energético para os sistemas de distribuição, podendo intensificar quedas de tensão em baixa tensão (BT), elevar perdas técnicas e provocar sobrecargas térmicas em condutores e transformadores. Neste trabalho, avaliou-se o impacto do carregamento veicular em um alimentador de distribuição a partir de simulações temporais no OpenDSS, integrado ao Python via opendssdirect.py. O sistema de estudo foi o alimentador IEEE 123 barras, adaptado ao padrão brasileiro (13,8 kV e 380/220 V), incluindo a representação explícita da conexão em BT por meio de uma rede auxiliar equivalente (BT_EQ). Foram considerados quatro cenários: BASE (sem VEs) e EV_10, EV_20 e EV_30, correspondentes a níveis de penetração de 10%, 20% e 30%, respectivamente. As simulações foram realizadas em modo Daily com passo ∆t = 1,0 h, e os indicadores avaliados incluíram níveis de tensão em BT (p.u.) com classificação equivalente ao PRODIST (Módulo 8), perdas técnicas totais (kWh/dia), carregamento de transformadores (% da potência nominal), carregamento térmico de linhas (% de NormAmps) e esforço de regulação (mudanças de tap). Os resultados evidenciaram degradação monotônica do desempenho elétrico com o aumento da penetração veicular: as perdas totais aumentaram de 524,00 kWh/dia (BASE) para 995,19 kWh/dia (EV_30), o que corresponde a um acréscimo de 471,19 kWh/dia, equivalente a 89,9% em relação ao caso BASE, enquanto o menor nível de tensão em BT reduziu-se de 0,9515 p.u. para 0,9325 p.u. Embora os valores de tensão permaneçam acima do limite inferior da faixa adequada do PRODIST, passaram a ocorrer períodos com V < 0,95 p.u. sob critério conservador, totalizando 3 h em EV_10, 4 h em EV_20 e 5 h em EV_30. Em termos de capacidade, o carregamento máximo de transformadores atingiu 149,14% no tx13 em EV_30, e o carregamento máximo de linhas alcançou 175,72% de NormAmps, evidenciando limitação crescente de capacidade térmica na rede. Conclui-se que, sob as premissas simuladas, a expansão da recarga veicular em baixa tensão reduz significativamente a margem operacional do alimentador e intensifica restrições térmicas na rede secundária, exigindo medidas de reforço e/ou estratégias de gestão do carregamento em cenários de maior penetração. | pt_BR |
| dc.publisher.country | Brasil | pt_BR |
| dc.publisher.department | Centro de Engenharia Elétrica e Informática - CEEI | pt_BR |
| dc.publisher.initials | UFCG | pt_BR |
| dc.subject.cnpq | Engenharia Elétrica | pt_BR |
| dc.title | Análise de impacto do carregamento veicular em redes de distribuição utilizando simulações no OpenDSS | pt_BR |
| dc.date.issued | 2026-03-18 | - |
| dc.description.abstract | The increasing penetration of electric vehicles (EVs) shifts part of the energy demand to distribution systems and may intensify voltage drops in low-voltage (LV) networks, increase technical losses, and cause thermal overloads in conductors and transformers. This study evaluated the impact of EV charging on a distribution feeder through timeseries simulations in OpenDSS, integrated with Python via opendssdirect.py. The study system was the IEEE 123-bus feeder, adapted to the Brazilian standard (13.8 kV and 380/220 V), including the explicit representation of LV connections through an equivalent auxiliary network (BT_EQ). Four scenarios were considered: BASE (without EVs) and EV_10, EV_20, and EV_30, corresponding to penetration levels of 10%, 20%, and 30%, respectively. Simulations were performed in Daily mode with a time step of ∆t = 1.0 h, and the evaluated indicators included LV voltage levels (p.u.) with classification equivalent to PRODIST (Module 8), total technical losses (kWh/day), transformer loading (% of nominal power), line thermal loading (% of NormAmps), and regulation effort (tap changes). The results showed a monotonic degradation in electrical performance as EV penetration increased: total losses rose from 524.00 kWh/day (BASE) to 995.19 kWh/day (EV_30), corresponding to an absolute increase of 471.19 kWh/day, equivalent to 89.9% relative to the BASE case, while the minimum LV voltage decreased from 0.9515 p.u. to 0.9325 p.u. Although voltage values remained above the lower limit of the adequate range defined by PRODIST, periods with V < 0.95 p.u. under a conservative criterion were observed, totaling 3 h in EV_10, 4 h in EV_20, and 5 h in EV_30. In terms of capacity, the maximum transformer loading reached 149.14% in tx13 under EV_30, and the maximum line loading reached 175.72% of NormAmps, indicating an increasing thermal capacity limitation in the network. It is concluded that, under the adopted assumptions, the expansion of EV charging in low voltage significantly reduces the feeder’s operational margin and intensifies thermal constraints in the secondary network, requiring reinforcement measures and/or load management strategies under higher penetration scenarios. | pt_BR |
| dc.identifier.uri | https://dspace.sti.ufcg.edu.br/handle/riufcg/48423 | - |
| dc.date.accessioned | 2026-10-22T11:50:10Z | - |
| dc.date.available | 2026-03-18 | - |
| dc.date.available | 2026-10-22T11:50:10Z | - |
| dc.type | Trabalho de Conclusão de Curso | pt_BR |
| dc.subject | veículos elétricos | pt_BR |
| dc.subject | redes de distribuição | pt_BR |
| dc.subject | OpenDSS | pt_BR |
| dc.subject | baixa tensão | pt_BR |
| dc.subject | PRODIST | pt_BR |
| dc.subject | perdas técnicas | pt_BR |
| dc.subject | carregamento térmico | pt_BR |
| dc.subject | electric vehicles | pt_BR |
| dc.subject | distribution networks | pt_BR |
| dc.subject | low voltage | pt_BR |
| dc.subject | technical losses | pt_BR |
| dc.subject | thermal loading | pt_BR |
| dc.rights | Acesso Aberto | pt_BR |
| dc.creator | LIRA, Emmanuel Messias Rodrigues de. | - |
| dc.publisher | Universidade Federal de Campina Grande | pt_BR |
| dc.language | por | pt_BR |
| dc.title.alternative | Analysis of the Impact of Vehicle Charging on Distribution Networks Using OpenDSS Simulations | pt_BR |
| dc.identifier.citation | LIRA, Emmanuel Messias Rodrigues de. Análise de impacto do carregamento veicular em redes de distribuição utilizando simulações no OpenDSS. 2026. 84f. Monografia (Bacharelado em Engenharia Elétrica) - Universidade Federal de Campina Grande, Centro de Engenharia Elétrica e Informática, Campina Grande, Paraíba, Brasil, 2026. Disponível em: https://dspace.sti.ufcg.edu.br/handle/riufcg/48423 | pt_BR |
| Appears in Collections: | Curso de Bacharelado em Engenharia Elétrica - CEEI - Monografias | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| EMMANUEL MESSIAS RODRIGUES DE LIRA - MONOGRAFIA – ENGENHARIA ELÉTRICA - (CEEI) 2026.pdf | EMMANUEL MESSIAS RODRIGUES DE LIRA - MONOGRAFIA – ENGENHARIA ELÉTRICA - (CEEI) 2026 | 3.34 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.