Please use this identifier to cite or link to this item: https://dspace.sti.ufcg.edu.br/handle/riufcg/48572
Title: Estágio integrado na Carpe Vie Engenharia Ltda.
Other Titles: Integrated internship at Carpe Vie Engenharia Ltda.
???metadata.dc.creator???: SANTOS, Edvaldo Raniere Ferreira Silva.
???metadata.dc.contributor.advisor1???: SOUZA, Benemar Alencar de.
???metadata.dc.contributor.referee1???: FERNANDES JÚNIOR, Damásio.
Keywords: Complexo Solar Afogados da Ingazeira;Fluxo de Potência;Curto-Circuito;Parecer de Acesso;Qualidade de Energia;Sistema Interligado Nacional;Access Opinion;Afogados da Ingazeira Solar Complex;National Interconnected System;Power Flow;Power Quality;Short-Circuit
Issue Date: 28-Jul-2026
Publisher: Universidade Federal de Campina Grande
Citation: SANTOS, Edvaldo Raniere Ferreira Silva. Estágio integrado na Carpe Vie Engenharia Ltda. 2026. 72f. Relatório de Estágio (Bacharelado em Engenharia Elétrica) - Universidade Federal de Campina Grande, Centro de Engenharia Elétrica e Informática, Campina Grande, Paraíba, Brasil, 2026. Disponível em: https://dspace.sti.ufcg.edu.br/handle/riufcg/48572
???metadata.dc.description.resumo???: A crescente integração de fontes de energia renovável, especi camente solar fotovoltaica, no Sistema Interligado Nacional (SIN) brasileiro tem evidenciado desa os signi cativos no escoamento de energia, especialmente na região Nordeste. Perante as restrições operativas da rede de transmissão, o presente trabalho teve como objetivo a elaboração do Parecer de Acesso para a integração do Complexo Solar Afogados da Ingazeira composto pelas UFVs Mandacaru (50 MW) e Macambira (50 MW), totalizando 100 MW ao barramento de 500 kV da Subestação Açu III, no Rio Grande do Norte. A metodologia baseou-se em simulações computacionais utilizando as ferramentas do CEPEL (ANAREDE, ANAFAS e HarmZs), avaliando cenários prospectivos do ONS para o horizonte dezembro de 2029, sob o cenário Nordeste Exportador Máxima Diurna. As análises abrangeram estudos de uxo de potência em regime permanente, contingências simples (critério N-1), níveis de curto-circuito e conformidade da qualidade da energia elétrica. Embora os resultados comprovem a viabilidade técnica do acesso quanto aos níveis de curto-circuito e à qualidade da energia elétrica esta última garantida mediante o projeto e validação de um ltro passivo RLC sintonizado para mitigar distorções na 7ª ordem harmônica , as simulações demonstraram que a injeção de potência da planta provoca um agravamento na sobrecarga da LT 230 kV Campina Grande II - Paraíso. Diante do esgotamento da capacidade de escoamento e do impacto sistêmico nessa linha de transmissão, conclui-se que a integração do projeto torna-se tecnicamente inviável no cenário operativo avaliado.
Abstract: The growing integration of renewable energy sources, speci cally solar photovoltaic, into the Brazilian National Interconnected System (SIN) has highlighted signi cant challenges in power transmission, especially in the Northeast region. Given the operational restrictions of the transmission grid, this study aimed to develop the Access Opinion (Parecer de Acesso) for the integration of the Afogados da Ingazeira Solar Complex composed of the Mandacaru (50 MW) and Macambira (50 MW) photovoltaic plants (UFVs), totaling 100 MW into the 500 kV bus of the Açu III Substation, in Rio Grande do Norte. The methodology was based on computational simulations using CEPEL software tools (ANAREDE, ANAFAS, and HarmZs), evaluating prospective ONS scenarios for the December 2029 horizon, under the Northeast Exporter Maximum Daytime Load scenario. The analyses encompassed steady-state power ow studies, simple contingencies (N-1 criterion), short-circuit levels, and power quality compliance. Although the results prove the technical viability of the connection regarding short-circuit levels and power quality the latter guaranteed by the design and validation of a tuned passive RLC lter to mitigate distortions at the 7th harmonic order , the simulations demonstrated that the power injection from the plant aggravates the overload on the Campina Grande II - Paraíso 230 kV transmission line. Given the exhaustion of the transmission capacity and the systemic impact on this transmission line, it is concluded that the integration of the project becomes technically unfeasible in the evaluated operational scenario.
Keywords: Complexo Solar Afogados da Ingazeira
Fluxo de Potência
Curto-Circuito
Parecer de Acesso
Qualidade de Energia
Sistema Interligado Nacional
Access Opinion
Afogados da Ingazeira Solar Complex
National Interconnected System
Power Flow
Power Quality
Short-Circuit
???metadata.dc.subject.cnpq???: Engenharia Elétrica
URI: https://dspace.sti.ufcg.edu.br/handle/riufcg/48572
Appears in Collections:Curso de Bacharelado em Engenharia Elétrica - CEEI - Relatórios de Estágio

Files in This Item:
File Description SizeFormat 
EDVALDO RANIERE FERREIRA SILVA SANTOS - RELATÓRIO DE ESTÁGIO – ENGENHARIA ELÉTRICA - (CEEI) 2026.pdfEDVALDO RANIERE FERREIRA SILVA SANTOS - RELATÓRIO DE ESTÁGIO – ENGENHARIA ELÉTRICA - (CEEI) 20263.35 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.