dc.description.resumoEste trabalho propõe duas metodologias, baseadas em modelos computacionais elétricos e térmicos via método dos Elementos Finitos, para avaliar o desempenho do sistema de isolamento de transformadores de corrente (TCs) ao longo da vida útil. A primeira metodologia aborda a avaliação de projeto e a otimização inicial do isolamento, com ênfase no posicionamento das camadas capacitivas, empregando o método de Nelder–Mead para reduzir o valor máximo global do campo elétrico. A segunda metodologia avalia a condição operacional do TC por meio de simulações térmicas multifísicas com Dinâmica dos Fluidos Computacional (CFD), considerando condições normais e adversas. A partir da temperatura de hot spot, aplica se o modelo de Montsinger para estimar a aceleração do envelhecimento. Os resultados demonstram que o modelo elétrico permite avaliar o projeto inicial e que a simplificação 2D com simetria de revolução apresenta aderência satisfatória ao modelo 3D. A aplicação da metodologia de otimização por meio do método de Nelder–Mead possibilitou reduzir em 24,77% o valor máximo do campo elétrico, quando associados anéis equalizadores às camadas capacitivas otimizadas. Na metodologia que emprega o modelo térmico, verificou-se que a operação com tangente de perdas acima do limite normativo, especialmente sob temperaturas ambiente elevadas, conduz à aceleração do envelhecimento do sistema de isolamento. Adicionalmente, a presença de pontos quentes iguais ou superiores a 100°C mostrou-se suficiente para promover degradação significativa do equipamento. A combinação de ponto quente e tangente de perdas acima do limite normativo intensifica o envelhecimento do sistema de isolamento.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleMetodologia de avaliação de transformadores de corrente de alta tensão sob diferentes condições operacionais.pt_BR
dc.date.issued2026-07-15-
dc.description.abstractThis work proposes two methodologies, based on electrical and thermal computational models using the Finite Element Method, to evaluate the performance of the insulation system of current transformers (CTs) throughout their service life. The first methodology focuses on design assessment and initial insulation optimization, with emphasis on the positioning of capacitive layers, employing the Nelder–Mead method to reduce the global maximum value of the electric field. The second methodology evaluates the operational condition of the CT through multiphysics thermal simulations using Computational Fluid Dynamics (CFD), considering both normal and adverse operating conditions. Based on the hot-spot temperature, the Montsinger aging model is applied to estimate the acceleration of thermal aging. The results demonstrate that the electrical model enables evaluation of the initial CT design and that the 2D axisymmetric simplification presents satisfactory agreement with the full 3D model. The application of the Nelder–Mead optimization methodology made it possible to reduce the maximum electric field value by 24.77% when grading rings were associated with the optimized capacitive layers. In the methodology employing the thermal model, it was verified that operation with a dissipation factor above the standard limit, especially under elevated ambient temperatures, leads to accelerated aging of the insulation system. Additionally, the presence of hot spots equal to or greater than 100°C was shown to be sufficient to promote significant equipment degradation. The combination of a hot spot and a dissipation factor above the standard limit further intensifies the aging of the insulation system.pt_BR
dc.identifier.urihttps://dspace.sti.ufcg.edu.br/handle/riufcg/48395-
dc.date.accessioned2026-10-20T12:43:51Z-
dc.date.available2026-10-20-
dc.date.available2026-10-20T12:43:51Z-
dc.typeTesept_BR
dc.subjectTransformadores de correntept_BR
dc.subjectMétodo dos elementos finitos .pt_BR
dc.subjectModelo computacional elétricopt_BR
dc.subjectModelo computacional térmicopt_BR
dc.subjectEnvelhecimento do transformador de correntept_BR
dc.subjectCurrent transformerspt_BR
dc.subjectFinite element methodpt_BR
dc.subjectElectrical computational modelpt_BR
dc.subjectThermal computational modelpt_BR
dc.subjectAging of the current transformerpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorLEITE NETO, Antônio Francisco.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeMethodology for evaluating high-voltage current transformers under different operating conditions.pt_BR
dc.description.sponsorshipCapespt_BR
dc.identifier.citationLEITE NETO, Antônio Francisco. Metodologia de avaliação de transformadores de corrente de alta tensão sob diferentes condições operacionais. 2026. 183 f. Tese (Doutorado em engenharia elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2026.pt_BR