Please use this identifier to cite or link to this item: https://dspace.sti.ufcg.edu.br/handle/riufcg/48548
Full metadata record
DC FieldValueLanguage
dc.creator.IDPEREIRA, R. L. A.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/0832997201886629pt_BR
dc.contributor.advisor1BRITO, Nubia Silva Dantas.-
dc.contributor.advisor1IDBRITO, Núbia Silva Dantaspt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9319631147408039pt_BR
dc.contributor.advisor2BRAZ, Helon David Macêdo.-
dc.contributor.advisor2IDBRAZ, H. D. M.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/4756997631027455pt_BR
dc.contributor.referee1FERNANDES JÚNIOR, Damásio.-
dc.contributor.referee2NEVES, Washington Luiz Araújo.-
dc.contributor.referee3LEÃO, Ruth Pastôra Saraiva.-
dc.contributor.referee4KAGAN, Elson.-
dc.description.resumoA crescente inserção de geração distribuída (GD) nos Sistemas de Distribuição de Energia Elétrica (SDEE) modifica os níveis e os sentidos das correntes de curto-circuito e de potência, podendo comprometer a coordenação e a seletividade dos sistemas convencionais de proteção diante de alterações topológicas e operacionais. Nesse contexto, esta tese propõe um Sistema de Proteção Adaptativo com Reconfiguração de Rede Integrados (SPARI) para SDEE com geração fotovoltaica distribuída, voltado à adaptação dos ajustes da proteção à reconfiguração da topologia da rede.A principal contribuição científica consiste na integração coordenada dessas funções, de modo que o isolamento e o restabelecimento do fornecimento sejam acompanhados da avaliação da coordenação da proteção e, quando necessário, do recálculo de seus ajustes para a nova condição operativa. O SPARI monitora as grandezas elétricas e os estados dos dispositivos, identifica e isola faltas permanentes, determina uma topologia de restabelecimento e adapta os parâmetros da proteção.A reconfiguração considera critérios topológicos e operacionais, priorizando o restabelecimento das cargas, além de prevenir violações de tensão. Para a otimização da coordenação da proteção, emprega-se o método híbrido ADEPI, que combina o Differential Evolution (Algoritmo Evolutivo Diferencial - ADE) e a Programação Linear (PL) para determinar os valores da corrente de pickup ($I_p$) e do Time Dial Setting (TDS), respeitando restrições de sensibilidade, seletividade e intervalo de coordenação.A metodologia foi implementada em Simulink/MATLAB® e OpenDSS, e avaliada nos sistemas-teste IEEE de 34 e 69 barras, sob diferentes condições de falta, níveis de penetração de GD e configurações topológicas. No sistema IEEE de 34 barras, a coordenação foi preservada em $83,33\%$ dos $264$ cenários e restabelecida pelo SPARI em $14,39\%$, totalizando $97,73\%$ de sucesso. No sistema IEEE de 69 barras, $466$ dos $480$ cenários apresentaram solução satisfatória, correspondendo a aproximadamente $97,08\%$ de sucesso. Nos casos com possibilidade de transferência de carga, foram restabelecidas aproximadamente $95\%$ das cargas interrompidas.Os resultados demonstraram que o SPARI permite associar o restabelecimento do serviço à adaptação da coordenação da proteção, estabelecendo novas topologias que consideram simultaneamente a continuidade do fornecimento e a adequação da proteção às condições elétricas resultantes.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqProcessamento da Energiapt_BR
dc.titleUm sistema integrado de proteção adaptativa e reconfiguração de redes para sistemas de distribuição de energia elétrica baseado em algoritmo diferencial evolutivo e programação linear.pt_BR
dc.date.issued2026-07-31-
dc.description.abstractThe increasing penetration of distributed generation (DG) in electric power distribution systems (EPDS) changes short-circuit current magnitudes and directions, as well as power flows, potentially compromising the coordination and selectivity of conventional protection systems under topological and operational changes. In this context, this thesis proposes an Integrated Adaptive Protection and Network Reconfiguration System (SPARI) for EPDS with distributed photovoltaic generation (PVG), integrating the adaptation of protection settings with network topology reconfiguration.The main scientific contribution is the coordinated integration of these functions, so that fault isolation and service restoration are accompanied by an assessment of protection coordination and, when necessary, by the recalculation of protection settings for the new operating condition. SPARI monitors electrical quantities and device states, identifies and isolates permanent faults, determines a service restoration topology, and adapts protection parameters.Network reconfiguration considers topological and operational criteria, prioritizing radiality and load restoration while also accounting for power losses and voltage violations. For protection coordination optimization, the hybrid ADE-PL method is employed, combining the Differential Evolutionary Algorithm (ADE) and Linear Programming (LP) to determine the pickup current ($I_p$) and Time Dial Setting (TDS) values, subject to sensitivity, selectivity, and coordination interval constraints.The methodology was implemented in Simulink/MATLAB and OpenDSS, and evaluated using the IEEE 34- and 69-bus test systems under different fault conditions, PVG penetration levels, and network topologies. In the IEEE 34-bus system, protection coordination was preserved in $83.33\%$ of the $264$ scenarios and restored by SPARI in $14.39\%$, resulting in an overall success rate of $97.72\%$. In the IEEE 69-bus system, $466$ of the $480$ scenarios yielded satisfactory solutions, corresponding to an overall success rate of approximately $97.08\%$. In scenarios where load transfer was feasible, approximately $80\%$ to $95\%$ of the interrupted loads were restored.The results demonstrate that SPARI enables service restoration to be integrated with the adaptation of protection coordination, establishing new network topologies that simultaneously account for continuity of supply and the adequacy of the protection system to the resulting electrical conditions.pt_BR
dc.identifier.urihttps://dspace.sti.ufcg.edu.br/handle/riufcg/48548-
dc.date.accessioned2026-11-17T19:32:54Z-
dc.date.available2026-11-17-
dc.date.available2026-11-17T19:32:54Z-
dc.typeTesept_BR
dc.subjectBusca em largurapt_BR
dc.subjectTeoria dos grafospt_BR
dc.subjectReconfiguração de redept_BR
dc.subjectProteção adaptativapt_BR
dc.subjectAlgoritmo diferencial evolutivopt_BR
dc.subjectBraditvirs Searchpt_BR
dc.subjectGraph Theorypt_BR
dc.subjectNetwork Recon urationpt_BR
dc.subjectAdaptive Protectionpt_BR
dc.subjectEvoluionary Differential Algorithmpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorPEREIRA, Ramayana Leonarda de Araújo.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeAn integrated system for adaptive protection and network reconfiguration in electric power distribution systems, based on a differential evolution algorithm and linear programming.pt_BR
dc.identifier.citationPEREIRA, Ramayana Leonarda de Araújo.Um sistema integrado de proteção adaptativa e reconfiguração de redes para sistemas de distribuição de energia elétrica baseado em algoritmo diferencial evolutivo e programação linear. 2026. 173 f. Tese (Doutorado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2026.pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
RAMAYANA LEONARDA DE ARAUJO PEREIRA - TESE - (PPGEE) 2026.pdf44.37 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.